{"id":1908,"date":"2020-06-05T17:08:54","date_gmt":"2020-06-05T08:08:54","guid":{"rendered":"https:\/\/www.tenox.co.jp\/wordpress\/?page_id=1908"},"modified":"2024-07-17T13:34:14","modified_gmt":"2024-07-17T04:34:14","slug":"ground_method_01","status":"publish","type":"page","link":"https:\/\/www.tenox.co.jp\/en\/construction_method\/ground_method_01\/","title":{"rendered":"TENOCOLUMN Method"},"content":{"rendered":"<div class=\"row sticky\">\r\n  <div class=\"col-md-3 menu-parent kouhou-parent wow fadeInUp\">\r\n  <div class=\"menu-side menu-side-kouhou\">\r\n    <h2><a href=\"\/en\/construction_method\/\">Method of Construction<\/a><\/h2>\r\n    <div class=\"menu-side-box\">\r\n      <h3>Pile Method<\/h3>\r\n      <ul class=\"side-s02\">\r\n        <li><a href=\"\/en\/construction_method\/pile_method_01\/\">TN-X Method<\/a><\/li>\r\n        <li><a href=\"\/en\/construction_method\/pile_method_02\/\">TN Method<\/a><\/li>\r\n        <li><a href=\"\/en\/construction_method\/pile_method_03\/\">Gantetsu Pile Method<\/a><\/li>\r\n        <li><a href=\"\/en\/construction_method\/pile_method_04\/\">NS ECO-PILE Method<\/a><\/li>\r\n        <li><a href=\"\/en\/construction_method\/pile_method_05\/\">ATTcolumn Method<\/a><\/li>\r\n        <li><a href=\"\/en\/construction_method\/pile_method_06\/\">CMJ Method<\/a><\/li>\r\n        <li class=\"nolink\">EAZET Method<\/li>\r\n        <li class=\"nolink\">HiFB Method<\/li>\r\n        <li class=\"nolink\">RODEX Method<\/li>\r\n      <\/ul>\r\n    <\/div>\r\n    <div class=\"menu-side-box\">\r\n      <h3>Ground improvement method<\/h3>\r\n      <ul class=\"side-s02\">\r\n        <li class=\"stay\">TENOCOLUMN Method<\/li>\r\n        <li><a href=\"\/en\/construction_method\/ground_method_02\/\">TENOCOLUMN ECO Method<\/a><\/li>\r\n        <li><a href=\"\/en\/construction_method\/ground_method_03\/\">TOFT Method<\/a><\/li>\r\n        <li><a href=\"\/en\/construction_method\/ground_method_04\/\">Pure Pile Method<\/a><\/li>\r\n        <li class=\"nolink\">Column Aproach Method<\/a><\/li>\r\n        <li class=\"nolink\">Multiwall Method<\/a><\/li>\r\n        <li class=\"nolink\">WIB Method<\/a><\/li>\r\n        <li class=\"nolink\">BASE BALANCE Method<\/a><\/li>\r\n        <li class=\"nolink\">CDM-LODIC Method<\/a><\/li>\r\n        <li class=\"nolink\">SAVE COMPOSER Method<\/li>\r\n      <\/ul>\r\n    <\/div>\r\n  <\/div>\r\n<\/div>\r\n\r\n  <div class=\"col-md-9\">\r\n    <div class=\"right-content kouhou-kui-ziban\">\r\n      <div class=\"content wow fadeInUp\">\r\n        <h2>TENOCOLUMN Method<span>Deep mixing processing method with high strength and low residual soil.<\/span><\/h2>\r\n        <h3>About The TENOCOLUMN Method<\/h3>\r\n        <p>TENOCOLUMN method is a deep-mixing processing method formed by stirring and mixing solidifying material liquid with the existing soil while injecting cement-based solidifying material (solidifying material liquid) made into a slurry at the in-situ position. This method is flexible and has a wide range of uses, including foundations for building structures, soil retaining, prevention of uneven settlement, and measures against liquefaction and arc sliding.<\/p>\r\n      <\/div>\r\n      <div class=\"content wow fadeInUp\">\r\n        <h3>Features<\/h3>\r\n        <div class=\"row\">\r\n          <div class=\"col-md-7\">\r\n            <ol class=\"ko-num\">\r\n              <li><span>For constructing high-quality columns.<\/span>By effectively stirring and mixing the soil, the Tenoblade (co-rotation prevention wing) forms a column of uniform strength for any soil quality.<\/li>\r\n              <li><span>Satisfying needs through an extensive lineup.<\/span>Tenox can manufacture column diameter ranging from 400 mm to 2,600 mm (Technology Review and Certification has been acquired). Tenox also offers construction equipment from 8 tons to 135 tons, and users can select according to the construction specifications and onsite conditions.<\/li>\r\n              <li><span>System for reliable construction management (Super System)<\/span>In the column building process, real-time management is performed for the number of times of stirring and mixing of excavation and stirring heads, the amount of added solidifying material, and the amount of work. This makes is possible to reduce the amount of cement used, shorten the construction period, and reduce costs.<\/li>\r\n              <li><span>An environmentally-friendly method.<\/span>This method has low vibration and low noise, and therefore has little impact on the surrounding environment. Furthermore, since the column is built to solidify the original soil, there is no groundwater pollution or secondary pollution.<\/li>\r\n            <\/ol>\r\n          <\/div>\r\n          <div class=\"col-md-5\">\r\n            <p><img decoding=\"async\" src=\"\/wordpress\/wp-content\/themes\/tenox\/images\/kouhou\/ground_method\/01\/01.jpg\" alt=\"\" class=\"img-responsive\"><span class=\"notes\">Drilling\/mixing head and Tenoblade<\/span><\/p>\r\n            <p><img decoding=\"async\" src=\"\/wordpress\/wp-content\/themes\/tenox\/images\/kouhou\/ground_method\/01\/02.jpg\" alt=\"\" class=\"img-responsive\"><span class=\"notes\">TENOCOLUMN digging situation<\/span><\/p>\r\n          <\/div>\r\n        <\/div>\r\n      <\/div>\r\n      <div class=\"content wow fadeInUp\">\r\n        <h3>Construction Methods<\/h3>\r\n        <p><img decoding=\"async\" src=\"\/wordpress\/wp-content\/themes\/tenox\/images\/kouhou\/ground_method\/01\/03.jpg\" alt=\"\" class=\"img-responsive\">\r\n        <ol class=\"ko-num\">\r\n          <\/p>\r\n          <li>The excavator and agitator are set on the column core.<\/li>\r\n          <li>The excavator stirrer is advanced via empty drilling to the specified foundation bottom level.<\/li>\r\n          <li>When the foundation bottom level is reached, solidifying material liquid is injected from the tip of the excavator and agitator, and the excavation is performed while stirring and mixing with the original soil.<\/li>\r\n          <li>After excavation is performed to the specified tip level, the tip is kneaded.<\/li>\r\n          <li>The construction is completed by withdrawing the excavator and agitator with reverse rotation.<\/li>\r\n        <\/ol>\r\n<p class=\"btn-02\" style=\"margin-top:30px;\"><a href=\"\/wordpress\/wp-content\/themes\/tenox\/images\/kouhou\/pdf\/leaflet_tenocolum.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Click Here for the Leaflet of the TENOCOLUMN Method<\/a><\/p>\r\n      <\/div>\r\n    <\/div>\r\n  <\/div>\r\n<\/div>\r\n","protected":false},"excerpt":{"rendered":"Method of Construction Pile Method TN-X Method TN Method Gantetsu Pile Method NS ECO-PILE Method ATTcolumn Method CMJ Method EAZET Method HiFB Method RODEX Method Ground improvement method TENOCOLUMN Method TENOCOLUMN ECO Method TOFT Method Pure Pile Method Column Aproach Method Multiwall Method WIB Method BASE BALANCE Method CDM-LODIC Method SAVE COMPOSER Method TENOCOLUMN MethodDeep mixing processing method with high strength and low residual soil. About The TENOCOLUMN Method TENOCOLUMN method is a deep-mixing processing method formed by stirring and mixing solidifying material liquid with the existing soil while injecting cement-based solidifying material (solidifying material liquid) made into a slurry at the in-situ position. This method is flexible and has a wide range of uses, including foundations for building structures, soil retaining, prevention of uneven settlement, and measures against liquefaction and arc sliding. Features For constructing high-quality columns.By effectively stirring and mixing the soil, the Tenoblade (co-rotation prevention wing) forms a column of uniform strength for any soil quality. Satisfying needs through an extensive lineup.Tenox can manufacture column diameter ranging from 400 mm to 2,600 mm (Technology Review and Certification has been acquired). Tenox also offers construction equipment from 8 tons to 135 tons, and users can select according to the construction specifications and onsite conditions. System for reliable construction management (Super System)In the column building process, real-time management is [&hellip;]","protected":false},"author":1,"featured_media":257,"parent":1380,"menu_order":166,"comment_status":"closed","ping_status":"closed","template":"templates\/page_templete_03.php","meta":{"_locale":"en_US","_original_post":"https:\/\/www.tenox.co.jp\/wordpress\/?page_id=727","_links_to":"","_links_to_target":""},"acf":[],"_links":{"self":[{"href":"https:\/\/www.tenox.co.jp\/wp-json\/wp\/v2\/pages\/1908"}],"collection":[{"href":"https:\/\/www.tenox.co.jp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.tenox.co.jp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.tenox.co.jp\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tenox.co.jp\/wp-json\/wp\/v2\/comments?post=1908"}],"version-history":[{"count":10,"href":"https:\/\/www.tenox.co.jp\/wp-json\/wp\/v2\/pages\/1908\/revisions"}],"predecessor-version":[{"id":61708,"href":"https:\/\/www.tenox.co.jp\/wp-json\/wp\/v2\/pages\/1908\/revisions\/61708"}],"up":[{"embeddable":true,"href":"https:\/\/www.tenox.co.jp\/wp-json\/wp\/v2\/pages\/1380"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tenox.co.jp\/wp-json\/wp\/v2\/media\/257"}],"wp:attachment":[{"href":"https:\/\/www.tenox.co.jp\/wp-json\/wp\/v2\/media?parent=1908"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}